• TIMING CHARGER

TIMING CHARGER

1.Can be easily controlled jog dial.
2.Build in 3 sets voltage, current storage and calling function.
3.Regular charge from 3M to 30H。
4.Highly radio-resistance and electromagnetic interference.
5.Overload protection, over heat protection and tracking over voltage protection function.

1.Can be easily controlled jog dial. 
2.Build in 3 sets voltage, current storage and calling function.
3.Regular charge from 3M to 30H。 
4.Highly radio-resistance and electromagnetic interference. 
5.Overload protection, over heat protection and tracking over voltage protection function.

Model

15V60A

30V30A

60V15A

Output voltage

1~15VDC

1~30VDC

1~60VDC

Output current

0~60A

0~30A

0~15A

Voltage Regulation

 

Load (10~100% load)

50mV

Line (170~264VAC variation)

20mV

Current Regulation

 

Load

200mA

150mA

100mA

Line(170~264VAC variation)

50mA

Ripple & Noise

 

Ripple & Noise (r.m.s) voltage

5mV

Ripple & Noise (peak-peak) voltage

50mV

50mV

100mV

Switching Frequency

65-85KHz~

75-95KHz~

65-85KHz~

Tracking Over Voltage Protections

O/P1~5v: setvoltage+2V

O/P5~15v:set voltage+3V

O/P1~5V:setvoltage+2V

O/P5~50V:setvoltage+3V

O/P20~30V:setvoltage+4V

O/P1~5V:setvoltage+2V

O/P5~20V:setvoltage+3V

O/P20~60V:setvoltage+4V

 

Meter Type & Accuracy

 

Voltage Meter

3 Digit LED Display±0.2% + 3counts

Current Meter

3 Digit LED Display±0.2% + 3counts

Display Resolution

Voltmeter:100mV    Anmeter:100mA

Input Voltage

100~120VAC,or 200~240 VAC 50/60Hz

Full Load Input Current

4.7A

4.5A

4.5A

Efficiency

85%

86%

88%

Power Factor Control

Power factor correction > 0.95 at optimal load

Cooling Method

Thermostatic Control Fan from Zero to full speed

Protections

Overload, Short Circuit by Constant Current, Output Tracking Over Voltage, Over Temperature